{"GrossTotalizer" } // 00000
{"AuthGrossTot" } // 00001
{"UnauthGrossTot" } // 00002
{"CreepGrossTot" } // 00003
{"RGrossTotalizer"} // 00004
{"RAuthGrossTot" } // 00005
{"RUnauthGrossTot"} // 00006
{"RCreepGrossTot" } // 00007
};
ppppp – Zero-based preset number (00000-00011).
lllll = Zero based additive number (00000-00015).
Modbus: Read/Write Register=298, Len=1, 16-Bit Integer (rrrrr)
Modbus: Read/Write Register=299, Len=1, 16-Bit Integer (ppppp)
Modbus: Read/Write Register= 300, Len=1, 16-Bit Integer (lllll)
If type -= SAMPLER_TOTALIZER_RT, rrrrrppppplllll
Where:
rrrrr – Sampler Totalizer Real Time Parameter Type as
custom_logic_sampler_totalizer_real_time_prompt[]
{
{"GrossTotalizer" } // 00000
{"RGrossTotalizer"} // 00001
};
ppppp – Zero-based preset number (00000-00011).
lllll = Zero based sampler number (00000-00003).
Modbus: Read/Write Register=298, Len=1, 16-Bit Integer (rrrrr)
Modbus: Read/Write Register=299, Len=1, 16-Bit Integer (ppppp)
Modbus: Read/Write Register= 300, Len=1, 16-Bit Integer (lllll)
7.1.15 107 – CUSTOM LOGIC VALUE REGISTERS
R107aaaaa => 0?0107aaaaavvvvvvvvv
U107aaaaavvvvvvvvv => 0?0107aaaaa (ONLY if the custom logic line is an external input)
Where:
aaaaa = The specified zero-based custom logic index (0000-1023).
vvvvvvvvv = The value read or to be written to the custom logic line.
Modbus: Read/Write Register=12000 +(aaaaa*2), Len=2, 32-Bit Integer (vvvvvvvvv)
This will return the value out of custom logic.
7.1.16 200 – STAND ALONE BOL DEFINITION REGISTERS
R200 => 0?0200aabbccddeeff