Chapter 7 Register Operations
90
PARITY_ODD 1
PARITY_EVEN 2
}
“Stop Bits” Select the number of stop bits for serial communication
Enum{// Enumerated Value Register Value
STOP_BITS_1 1
STOP_BITS_2 2
}
“Multidrop” Select which Multidrop mode to use
Enum{// Enumerated Value Register Value
MULTIDROP_SINGLE 0
MULTIDROP_MULTI 1
MULTIDROP_2WIRE 2
}
“Communication Type” Select which communication type to use for a serial port
Enum{// Enumerated Value Register Value
COMMUNICATION_TYPE_NA 0
COMMUNICATION_TYPE_HOST 1
COMMUNICATION_TYPE_FCM 2
COMMUNICATION_TYPE_PRINT 3
COMMUNICATION_TYPE_LOG 4
COMMUNICATION_TYPE_ETHERNET 5
COMMUNICATION_TYPE_ALIBILOG 6
COMMUNICATION_TYPE_PTB_ALIBI 7
}
“Tank Mode” Select the mode of operation for the tank
Enum{// Enumerated Value Register Value
TANK_MODE_DEACTIVE 0
TANK_MODE_LOADING 1
TANK_MODE_UNLOADING 2
TANK_MODE_LOAD_UNLOAD 3
}
“Security Complexity Mode” Select the password complexity that is required when creating a password for user
accounts
Enum{// Enumerated Value Register Value
SECURITY_COMPLEXITY_TYPE_NONE 0
SECURITY_COMPLEXITY_TYPE_ALPHA 1
SECURITY_COMPLEXITY_TYPE_NUMERIC 2
SECURITY_COMPLEXITY_TYPE_ALPHA_NUMERIC 3
SECURITY_COMPLEXITY_TYPE_SPECIAL_CHAR 4
SECURITY_COMPLEXITY_TYPE_ALPHA_SPECIAL_CHAR 5
SECURITY_COMPLEXITY_TYPE_NUMERIC_SPECIAL_CHAR 6