Chapter 7 Register Operations
89
“Decimal Mark” Select which decimal is used in each screen
Enum{// Enumerated Value Register Value
DECIMAL_MARK_TYPE_DECIMAL = 0,
DECIMAL_MARK_TYPE_COMMA = 1
}
“Flow Rate Mode” Select which rate is used in each screen
Enum{// Enumerated Value Register Value
FLOW_RATE_MODE_MINUTES = 0,
FLOW_RATE_MODE_HOURS = 1
}
“Api Astm D1555” Select which product to use for the D1555 table
Enum{// Enumerated Value Register Value
API_ASTM_D1555_PRODUCT_TYPE_NO_PRODUCT =0,
API_ASTM_D1555_PRODUCT_TYPE_BENZENE =1,
API_ASTM_D1555_PRODUCT_TYPE_CUMENE =2,
API_ASTM_D1555_PRODUCT_TYPE_CYCLHEX =3,
API_ASTM_D1555_PRODUCT_TYPE_ETHYLBE =4,
API_ASTM_D1555_PRODUCT_TYPE_STYRENE =5,
API_ASTM_D1555_PRODUCT_TYPE_TOLUENE =6,
API_ASTM_D1555_PRODUCT_TYPE_MXYLENE =7,
API_ASTM_D1555_PRODUCT_TYPE_OXYLENE =8,
API_ASTM_D1555_PRODUCT_TYPE_PXYLENE =9,
API_ASTM_D1555_PRODUCT_TYPE_300_350 =10,
API_ASTM_D1555_PRODUCT_TYPE_350_400 =11
}
“Baud Rate” Select which baud rate to use for serial communications
Enum{// Enumerated Value Register Value
BAUD_RATE_300 0
BAUD_RATE_1200 1
BAUD_RATE_2400 2
BAUD_RATE_4800 3
BAUD_RATE_9600 4
BAUD_RATE_19200 5
BAUD_RATE_38400 6
BAUD_RATE_57600 7
BAUD_RATE_115000 8
BAUD_RATE_230000 9
}
“Data Bits” Select the number of data bits to use for serial communication
Enum{// Enumerated Value Register Value
DATA_BITS_7 0
DATA_BITS_8 1
}
“Parity” Select which parity bit types to use for serial communication
Enum{// Enumerated Value Register Value
PARITY_NONE 0