Chapter 7 Register Operations
88
“Alarm to Host Mode” Select if the alarm needs to be send to the host
Enum{// Enumerated Value Register Value
DISABLED = 0,
ENABLED = 1
}
“Mass Measures” Select the UOM of Mass
Enum{// Enumerated Value Register Value
NO_MASS_MEASURES = 0,
MASS_POUNDS = 1,
MASS_SHORT_TONS = 2,
MASS_LONG_TONS = 3,
MASS_GRAMS = 4,
MASS_KILOGRAMS = 5,
MASS_KILOGRAMS_AIR = 6,
MASS_METRIC_TONS = 7,
}
“Delivery Type” Select the UOM in which the product needs to be delivered
Enum{// Enumerated Value Register Value
DELIVERY_TYPE_GROSS = 0,
DELIVERY_TYPE_NET = 1,
DELIVERY_TYPE_MASS = 2
}
“Blend Type” Select which type of blending is used.
Enum{// Enumerated Value Register Value
BLEND_TYPE_NONE = 0,
BLEND_TYPE_RATIO =1,
BLEND_TYPE_SEQUENTAIL = 2,
BLEND_TYPE_RATIO_AND_SEQUENTAIL = 3,
BLEND_TYPE_WATERCUT = 4,
}
“Temperature_UOM Type” Select which type of temperature UOM is used.
Enum{// Enumerated Value Register Value
TEMPERATURE_UOM_TYPE_CELSIUS = 0,
TEMPERATURE_UOM_TYPE_FAHRENHEIT = 1
}
“Additive Mode” Select which mode of additive is used.
Enum{// Enumerated Value Register Value
ADDITIVE_MODE_START_ON_BATCH = 0,
ADDITIVE_MODE_START_ON_HIGH_FLOW = 1,
ADDITIVE_MODE_START_ON_VOLUME = 2
}