{"*FCM CONF" }, // 00002
{"*FCM WDT" }, // 00003
{"*FCM TMOUT" }, // 00004
{"*VALVE FLT" }, // 00005
{"*LOW FLOW" }, // 00006
{"*EXCESS FL" }, // 00007
{"*QUAD ENC" }, // 00008
{"*DENSITY" }, // 00009
{"*RTD ERROR" }, // 00010
{"*VALVE CTL" }, // 00011
{"*MTR CREEP" }, // 00012
{"*PRES ALRM" }, // 00013
{"*QUAD CH A" }, // 00014
{"*QUAD CH B" }, // 00015
{"*MTR COM" }, // 00016
{"*GRAVITY" }, // 00018
};
ppppp – Zero-based preset number (00000-00011).
lllll = Zero based meter number (00000-00003).
Modbus: Read/Write Register=298, Len=1, 16-Bit Integer (rrrrr)
Modbus: Read/Write Register=299, Len=1, 16-Bit Integer (ppppp)
Modbus: Read/Write Register=300, Len=1, 16-Bit Integer (lllll)
If type -= ADDITIVE_RT_ALARM, rrrrrppppplllll
Where:
rrrrr – Additive Real Time Alarm Parameter Type as
custom_logic_additive_real_time_alarm_prompt[]
{
{"*ADTV FCM" } // 00000
{"*ADTV PERM" }, // 00001
{"*UND ADTV" }, // 00002
{"*OVR ADTV" }, // 00003
{"*VALVE FLT" }, // 00004
{"*PUMP STAT" }, // 00005
{"*INJCT FLT" }, // 00006
{"*UNAUTH FL" }, // 00007
{"*NO LNFLSH" }, // 00008
{"*MTR CREEP" }, // 00009
{"*BLK VALVE" }, // 00010
};
ppppp – Zero-based preset number (00000-00011).
lllll = Zero based additive number (00000-00015).
Modbus: Read/Write Register=298, Len=1, 16-Bit Integer (rrrrr)
Modbus: Read/Write Register=299, Len=1, 16-Bit Integer (ppppp)
Modbus: Read/Write Register=300, Len=1, 16-Bit Integer (lllll)