Mass Positions are not available via Modbus protocol
R300iiill => 0?0300iiill…
U300iiill… => 0?0300iiill
Where:
iii = BOL Literal Line Index (0-29)
Note: For Modbus, the Modbus Custom Logic Index Register sets the iii index.
Modbus: Read/Write Register=417, Len=1, 16-Bit Integer (iii)
ll = BOL Line Number
… = Literal String (Max 80 Characters)
Modbus:
Read/Write Register=418, Len=1, 16-Bit Integer (ll)
Read/Write Register=419, Len=80, Characters (…)
Note: Last Register Used=498
R410iil => 0?0410iilaabbcc…
U410iilaabbcc… => 0?0410iil
Where:
ii = Prompt Index (0-3)
l = Language Index (0-8)
aa = Input Length (0-19)
bbcc = BOL Line and Position Number
… = Prompt String (Max 20 Characters)
Modbus:
l = Language Index (0-1)
Read/Write Register=550+23*(2*ii+l), Len=1, 16-Bit Integer (aa)
Read/Write Register=551+23*(2*ii+l), Len=1, 16-Bit Integer (bb)
Read/Write Register=552+23*(2*ii+l), Len=1, 16-Bit Integer (cc)
Read/Write Register=553+23*(2*ii+l), Len=20, Characters (…)
Read/Write Register=554+23*(2*ii+l), Len=20, Characters (…)
Note: Last Prompt Register Used=733
Note:
Prompt5 cannot be updated via Modbus
R420iii => 0?0420iii…
U420iii… => 0?0420iii
Where:
iii = Hazard Index (0-4)
… = Hazard String (Max 40 Characters)
Modbus:
Read/Write Register=734+40*iii, Len=40, Characters (…)
Note: Last Register Used=833