Chapter 7 Register Operations
13
3
Read/Write Register=7842, Len=25, Characters (bbbb)
Read/Write Register=7867, Len=25, Characters (cccc)
Read/Write Register=7892, Len=25, Characters (dddd)
Read/Write Register=N/A, Len=25, Characters (eeee)
if BOL Detail Line Index > 00,
IIBBBBppptthhhccccccgggggggggnnnnnnnnnttttddddmmrrrrssssssttttuuuuuuvvvvvww
wxxxxxxxxzzzzzzzzzaaaaabbbbbbccccccddddd
(or)
IIIIBBBBppptthhhccccccgggggggggnnnnnnnnnttttddddmmrrrrssssssttttuuuuuuvvvvvww
wxxxxxxxxxzzzzzzzzzaaaaabbbbbbccccccdddddeeeeee
II (or) IIII = BOL Detail Line Index
BBBB = BOL Transaction Number
ppp = Preset Number
tt = Detail Type,
‘1’ – Saleable Product,
‘2’ – Component,
‘3’ – Additive,
‘4’ – Meter,
‘5’ – Sampler,
‘6’ – Free,
7 Preset Totalizer,
8 Meter Totalizer,
9 Component Totalizer,
10 Additive Totalizer
‘11’ – Sampler Totalizer
‘12’ – Free Totalizer
hhh = Legacy Header Index (not used)
cccccc = Product Code
ggggggggg = Gross Volume
nnnnnnnnn = Net Volume
Note: if the Use Hundredths W&M RCU parameter is enabled, the gross and net quantity value will have an implied two decimal places.
tttt = Average Temp
dddd = Gravity or Density (do not use for relative density)
mm = Compartment
rrrr = Average Pressure
ssssss = api_expansion_coef_tenths
ttttt = corrected_densitygravity
uuuuuu = volume_correction_factor
vvvvv = bsw_hund
wwww = alibilog_alarm
xxxxxxxxx = batch_number
zzzzzzzzz = mass_del
aaaaa = temperature in hunds
bbbbbb = ctl
cccccc = cpl