Chapter 7 Register Operations
15
0
enum
{
AUTO_CLEAR = 0,
DRIVER_CLEAR = 1,
REMOTE_CLEAR = 2,
PROGRAM_CLEAR = 3,
WM_CLEAR = 4
}promoted_alarm_level;
rrrrr = Reset Mode as:
enum
{
AUTH_TRANS = 0,
CLEAR_PROMOTED = 1,
TIME_2_MIN = 2,
TIME_5_MIN = 3,
TIME_15_MIN = 4,
TIME_30_MIN = 5,
TIME_60_MIN = 6,
TIME_3_HOURS = 7,
TIME_6_HOURS = 8,
TIME_12_HOURS = 9,
TIME_24_HOURS = 10,
}alarm_count_reset_mode;
ttttt = Alarm_to_host as
enum
{
REMOTE = 0,
LOCAL =1,
}alarm_to_host_mode_type
Note: only permissive names can be changed, iii=1.
Mmmmmmmmm = Fcm Output Address
Nnnnn = Batch Alarm Mask for Alibilog
Enum{ DISABLED = 0,
ENABLED = 1 }
Modbus:
Read/Write Register=2521, Len=1, 16-Bit Integer (lllll)
Read/Write Register=2522, Len=15, Characters (sssssssssssssss)
Note: Up to 15 UTF-8 bytes to represent a max of 10 characters.
Read/Write Register=2537, Len=1, 16-Bit Integer (ccccc)
Read/Write Register=2538, Len=1, 16-Bit Integer (ppppp)
Read/Write Register=2539, Len=1, 16-Bit Integer (rrrrr)
Read/Write Register=cannot be accessed, Len=1, 16-Bit Integer (ttttt)
Read/Write Register=cannot be accessed, Len=1, 16-Bit Integer (mmmmmmmmm)
Read/Write Register=cannot be accessed, Len=1, 16-Bit Integer (nnnnn)