Chapter 8 Communication Trace Example
169
Sent:(Q) Received: (0a1C61A)
...(some time later)...
Sent:(Q) Received: (0a1CA1A)
Modbus:
Fn=0x03, Read Register 7002 -> (0xC61A)
...(some time later)...
Fn=0x03, Read Register 7002 -> (0xCA1A)
Get driver input and terminating key
Sent:(R960) Received: (0a19601 )
Sent:(R961) Received: (0a1961D)
Modbus:
Fn=0x03, Read Registers 2850 ... 2875
Prompt for preset quantity
Sent:(T_H_K_>Enter Preset #01 Qty: _@_L06_E) Received: (0a1)
Modbus:
Use Extended Services Register
Wait for driver input done
Sent:(Q) Received: (0a1C61A)
...(some time later)...
Sent:(Q) Received: (0a1CA1A)
Modbus:
Fn=0x03, Read Register 7002 -> (0xC61A)
...(some time later)...
Fn=0x03, Read Register 7002 -> (0xCA1A)
Get driver input and terminating key
Sent:(R960) Received: (0a19601000 )
Sent:(R961) Received: (0a1961D)
Modbus:
Fn=0x03, Read Registers 2850 ... 2875
Upload selected recipe definitions into index in range of 001-019 (recommend using preset number as index).
Sent:(U5000010001100Regular Unlead RUL
02010000000000000000000000000000000000000000000000000000000000000000000000000000000000000
00000000000000000000000) Received: (0a1)
Modbus:
Fn=0x06, Write Index 1 to Register 2200
Fn=0x16, Write Recipe Data to Registers 2201 … 2267
Authorize preset for batch indicating volume and recipe definition index.
Sent:(MAM000100100000100000) Received: (0T1)
Modbus:
Fn=0x16, Write Authorization Data (1, 0, 1000, 1, 1) to Registers 7500 … 7504