EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 34: 48 Volt Keyswitch Undervolt - Reel Motor 2

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault34:48VoltKeyswitchUndervolt
ReelMotor2
InfoCenterDisplay:
____FAULT#34____
248V
KEYSWITCHUNDER
V
Important:Forthisfault,theterm“keyswitch”referstothe48Vlogicpowercircuit,nottothe
ignitionswitch.
FaultDescription
Thisfaultisreportedwhenthe48Vsystemvoltagedropsbelow32Vatcuttingunit2.
CircuitDescription
Eachcuttingunithasanelectricreelmotorthatcontainsaninternalcontroller.Theinternalcontrollermeasures
asteady48Vsignal,calledlogicpower.
Ifonly1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobewiththe48V
logicpowerconnectiontothatcuttingreelmotor.
Ifmorethan1cuttingreelmotorisreportingakeyswitchundervoltfault,theproblemismorelikelytobe
withthe48Vbusvoltage.
Ifmorethanonedeviceisreportingthisfault,checkthebatteryvoltagewiththeengineOFF,andagainwith
theenginerunning.
IfthebatteryvoltageisgoodwithengineOFFbutnotON,checktheStarter/Generator.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:ChecktheInfoCenterfortheReelsEnableindication.
TheReelsEnableindicationontheInfoCenterDiagnosticsscreenidentieswhethertheTEC-5001outputexists
toenergizethe48VLogicrelayThisrelayprovides48Vlogicpowertothereelmotorsandstarter/generator.
114