EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 39: Master TEC Internal Error

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault39:MasterTECInternalError
InfoCenterDisplay:
____FAULT#39____
TEC5001MASTER
TECFAILURE
FaultDescription
ThisfaultisreportedwhentheprimaryTECdetectsaninternalhardwarefault.
CircuitDescription
TheprimaryTECmonitorstheconditionofvariousmachineswitchesandsensors(inputs)anddirectselectrical
powertocontrolmachinefunctions(outputs)basedonthestateoftheinputs.TheprimaryTECisprimarily
responsibleformanagingtheenginestartsignalandinterlocks.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19)
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testthe12VBatteryVoltage.
ReferenceChecktheConditionofthe12VBattery(page16)andtestthecapabilityofthe12Vbattery.
Pass
Thebatterypassedthevoltageandloadtest.GotoStep3.
Fail
The12Vbatterydidnotpassthevoltageand/orloadtesting.Replacethe12Vbattery.Goto
ReturningtheMachinetoService(page21)andfollowthestepslisted.
Step3:SwaptheprimaryTECwithaknowngoodunit.
Note:TECcontrollersareprogrammedtospecicmachinemodelandserialnumbers.TECcontrollersdonot
functionuntilprogrammedbyT oroDIAG.
TherearethreeproceduresthatyouneedtoaccomplishaspartofreplacingaTEC.RefertoReplacingaToro
ElectronicController(TEC)(page23).
1.UseT oroDIAGtosavethemachinetimersandcountersleoutoftheoriginalTEC.(page23)
2.ReplacetheTEC.(page24)
3.UseToroDIAGtoprogramtheTEC,andthenrestoretheTD2le.(page25)
4.DuplicatetheoperationofthemachinewhenthefaultoccurredwiththeoriginalprimaryTEC.
134