Toro Greensmaster TriFlex 3400 - Fault 128: Short Detected - Unknown Reel Motor

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault128:ShortDetectedUnknownReel
Motor
InfoCenterDisplay:
_____FAULT#128____
UNKNOWN-
SHORTED
FaultDescription
Oneofthethreereelmotorshasaninternalshortcircuit.TheTECisunabletodenewhichmotorhasthe
problem.
CircuitDescription
Thethreecuttingreelmotorsinthemachineareidentical48V,1100watt,brushless,permanentmagnet
motors.Eachmotorhasitsownintegralinverterandon-boardcontroller.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Disconnectall3reelmotorsandrecheckforthefault.
Thisstepwillshowwhetherthefaultiscausedbyareelmotor.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Disconnect48Vpowerfromthecuttingunitsbyseparatingthecuttingunitpowerconnectors.This
preventsunexpectedoperationofcuttingunits.RefertoConnectingandDisconnectingthe48VPower
totheCuttingReelMotors(page18).
3.Locateanddisconnectthe2cuttingreelmotorconnectorsfromthee-reelsharnessconnectorsP17
andP18forcuttingunit1.(Figure167).
300