EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 43: Hydraulic Oil Temperature Sensor - Overtemp

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault43:HydraulicOilTemperatureSensor
Overtemp
InfoCenterDisplay:
____FAULT#43____
HYD.OILSENSOR
FaultDescription
Thisfaultisreportedwhenthehydraulicuidtemperatureismeasuredabove95ºC(203ºF).Thisfaultcouldbe
theresultofahightemperatureconditioninthehydrauliccircuitoradefectinthetemperaturemonitoringsystem.
CircuitDescription
Thehydraulicuidtemperaturesensorisattachedtothehydraulictank.Theresistanceofthetemperature
sensordecreasesastheuidtemperatureinthetankincreases.Thehydraulicuidtemperaturesensorisan
inputtothestatusdisplayandprovidesinformationforthehydraulictemperaturegauge.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testthehydraulictempsender.
1.Removethehydraulictemperaturesenderfromthemachine.
2.Followtheservicemanualproceduretotestthetempsender.
Pass
Thesenderpassedthefunctiontest.Installitbackintothemachine.GotoStep3.
Fail
Thesenderdidnotpassthefunctiontest.Replacethehydraulictemperaturesender.GotoReturning
theMachinetoService(page21)andfollowthestepslisted.
Step3:Testthecontinuityofthehydraulictempsenderwiring.
1.Disconnectthehydraulictemperaturesenderconnector(P57).
2.DisconnecttheconnectorfromtheprimaryTEC(P01).
3.Usingamultimeter,testthewiresshownbelowforcontinuity.
138

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals