Fault63:IDModuleFault
InfoCenterDisplay:
_____FAULT#63_____
IDMODULEFAULT
FaultDescription
ThisfaultisreportedwhenaninternaldigitallocationIDcode(address)ismissingfromacomponent,orifmore
than1cuttingreelmotorreportshavingthesameCANIDastheprimaryTEC.TheprimaryTECcontrollerhas
recognizedatleastoneofthecuttingunitelectronicaddressesisoutsideofthestandardrange.
CircuitDescription
ThelocationIDmoduleexistsintheelectriccuttingreelscircuittoidentifythelocationofeachofthethree
cuttingreelmotors.Thismoduleallowsmachinefeaturessuchasraisingthecentercuttingunitslightlylater
thanthefrontcuttingunits,andmonitoringofspecicreelperformancebylocation.Thelocationmoduleplugs
intothee-reelswireharnessundertheleftsidecover,nexttotheoperatorseat.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:TesttheresistanceoftheIDmodule.
TheIDmoduleislocatedunderneaththeleft-handcoverassembly(Figure93).RefertotheGreensmaster
TriFlex3320/3420ServiceManual,Chapter6,LocationIDModulesection,andtesttheIDmodule.