Fault102:48VKeySwitchOvervolt
Starter/Generator
InfoCenterDisplay:
_____FAULT#102____
-48VKEYSWITCH
OVERV
Important:Forthisfault,theterm“keyswitch”referstothe48Vlogicpowercircuit,nottotheignition
keyswitch.
FaultDescription
Thestartergenerator(S/G)controllerhasdetectedthat48Vlogicpowerhasexceededthe65Vhighvoltage
limit.
CircuitDescription
TheS/Gsharesthe48Vlogicpowerwithall3electriccuttingreelmotors.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Determinethetroubleshootingstrategy.
IfonlytheS/Gisreportinga48VKeySwitchOvervoltfault,theproblemismorelikelytobewiththe48Vlogic
powerconnectiontotheS/G.
Ifmorethan1cuttingreelmotorandtheS/Garebothreportinga48VKeySwitchOvervoltfault,theproblemis
morelikelytobewiththe48Vsystemvoltage.PerformtheRecommendedServiceActionsforfault46.
Step3:Withtheengineshutoff,checkthe48Vbatterysystem.
The48Vbatterypackiscomposedof4sealed12Vbatteries,connectedinseries.
1.Gainaccesstothebatteriesbyremovingthecoverontheleftsideofthemachine.
2.Locatethe48Vcontactor.
3.Useamultimetertomeasurethevoltageofthe48Vbatterypackacrossthemaincontactor.Thereading
shouldbe46–54volts.
4.Ifthevoltagereadslow,performthe48VbatterypackserviceasshowninChapter6oftheGreensmaster
TriFlex3320/3420ServiceManual.
5.T estthevoltageoneachindividualbattery.Theacceptablerangeis11.5–13.5V.