Toro Greensmaster TriFlex 3400 - Fault 84: Electronic Reel Motor Enable - Current High

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault84:ElectronicReelMotorEnable
CurrentHigh
InfoCenterDisplay:
_____FAULT#84_____
eREELENABLE-
OVER
FaultDescription
Thisfaultisreportedwhenthe48Vlogicrelayoutputcurrentistoohigh.
CircuitDescription
AfterarequestissenttotheprimaryTEC,the48Vlogicrelaysendsanoutputsignaltothecuttingunitto
beginworkatapredeterminedspeed.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.