Fault114:InternalRegulatorLowVoltage
ReelMotor3
InfoCenterDisplay:
_____FAULT#114____
3-INTERNAL
UNDERV
FaultDescription
Insufcientvoltagewasdetectedattheinternalvoltageregulatorforcuttingreelmotor3.Thisfaultcanoccur
ifthecuttingreelmotorunexpectedlylosespower.Forexample,ifthecuttingreelmotorconnectorispulled
apartwhenpowered,thisfaultisreported.
CircuitDescription
Eachcuttingreelmotorhasaninternalvoltageregulator.
Note:Theinternalvoltageregulatorisnotaserviceablepart.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotor3.
1.Locatethe2cuttingreelmotorconnectorsandthee-reelsharnessconnectorsP21andP22.