EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 95: 48 V Bus Low Voltage - Reel Motor 2

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault95:48VBusLowVoltageReelMotor
2
InfoCenterDisplay:
_____FAULT#95____
2-48VPOWER
BUSUNDERV
FaultDescription
Thisfaultisreportedwhenthereelmotorcontrollerdetects48Vbuspowerdropsbelow32V.
CircuitDescription
All3cuttingreelmotorssharethe48Vlogicpowerwiththemotor/generator.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotorposition2.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Unplugthe48Vbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnectingand
Disconnectingthe48VPowertotheCuttingReelMotors(page18).
3.Followthecuttingreelmotorcablefromcuttingreelmotor1totheconnectorsmountedonthetractionunit.
Note:The2cuttingreelmotorcableconnectorsaresecuredwithclipstotheconnectorplate.The2
e-reelharnessconnectorsarenotsecuredtotheconnectorplate.
4.Disconnectthee-reelharnessconnectorsP19andP20fromthe2cuttingreelmotorcableconnectors.
5.Inspectthe2cuttingreelmotorcableconnectorsandthe2e-reelharnessconnectorsforthefollowing:
damage
corrosion
debris
properalignmentandseatingofthepinsinsidetheconnectors
6.Inspectthe2cuttingreelmotorcableconnectorsforproperwirecolorperpin,asshowninthefollowing2
tables.
CuttingReelMotor,4-PinConnector
230

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals