Toro Greensmaster TriFlex 3400 - Fault 127: Short Detected - Reel Motor 3

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault127:ShortDetectedReelMotor3
InfoCenterDisplay:
_____FAULT#127____
3-SHORTED
FaultDescription
Thereelmotorincuttingunit3hasaninternalshortcircuit.
CircuitDescription
Thethreecuttingreelmotorsinthemachineareidentical48V,1100watt,brushless,permanentmagnet
motors.Eachmotorhasitsownintegralinverterandon-boardcontroller.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.Disconnectthe48Vpowertothecuttingreelmotors.RefertoConnectingandDisconnectingthe48
VPowertotheCuttingReelMotors(page18).
2.RefertoFigure166tolocatecuttingunit3.