EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 71: S2 Lower - Current too High

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault71:S2LowerCurrentTooHigh
InfoCenterDisplay:
_____FAULT#71_____
S2COIL-OVER
FaultDescription
ThisfaultisreportedwhentheprimaryTEC-5001controllerdeterminesthattheS2coilcurrentistoohigh.
CircuitDescription
TheprimaryTEC-5001controllerusesinputsfromvariousmachineswitchestodeterminewhentoenergizelift
manifoldsolenoidvalves.OneoutputfromtheprimaryTEC-5001controllerdrivesthecoilforsolenoidS2.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:TesttheresistanceofthecoilforsolenoidS2.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Removetherightsidecover(Figure102).
180

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals