Fault98:48VKeySwitchOvervoltReel
Motor1
Important:Forthisfault,theterm“keyswitch”referstothe48Vlogicpowercircuit,nottotheignition
keyswitch.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____FAULT#98____
1-48V
KEYSWITCHOVERV
FaultDescription
Cuttingreelmotor1hasdetectedthatthe48Vlogicvoltagehasexceededthehighvoltagelimitof67.5V.This
faultcausesthecuttingreelmotortobedisabled.
Note:All48Vdevicesareconnectedtothesame48Vbus.Ifthisisasystemissue,theprimaryTEC
combinesall48VKeySwitchOvervoltfaultsintoasinglefault.
CircuitDescription
All3cuttingreelmotorssharethe48Vlogicpowerwiththestarter/generator.
Note:ThisfaultcanalsooccuriftheprimaryTEClosescommunicationwiththemotor/generator.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Determinethetroubleshootingstrategy.
Ifonly1cuttingreelmotorisreportinga48VKeySwitchOvervoltfault,theproblemismorelikelytobewiththe
48Vlogicpowerconnectiontothatcuttingreelmotor.GotoStep3.
Ifmorethan1cuttingreelmotorisreportinga48VKeySwitchOvervoltfault,theproblemismorelikelytobe
withthe48Vsystemvoltage.PerformtheRecommendedServiceActionsforfault46.
Step3:Inspectthewiringforcuttingunit1.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.