Toro Greensmaster TriFlex 3400 - Fault 67: S1 Enable - Current too High

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault67:S1EnableCurrentTooHigh
InfoCenterDisplay:
_____FAULT#67_____
S1COIL-OVER
FaultDescription
ThisfaultisreportedwhentheprimaryTEC-5001controllerdeterminesthattheS1solenoidcoilcurrent
istoohigh.
CircuitDescription
TheprimaryTECcontrollerusesinputsfromvariousmachineswitchestodeterminewhentoenergizelift
manifoldsolenoidvalves.OneoutputfromtheprimaryTECcontrollerdrivesthecoilforsolenoidS1.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:TesttheresistanceofthecoilforsolenoidS1.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Removetherightsidecover.
173