Toro Greensmaster TriFlex 3400 - Fault 86: 48 V Bus Overvoltage - Reel Motor 1

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault86:48VBusOvervoltageReelMotor
1
InfoCenterDisplay:
_____FAULT#86____
1-48VPOWER
BUSOVERV
FaultDescription
Note:Reelmotor1isinthecenterposition.
Thisfaultisreportedwhenthecuttingreelmotormeasuresasystemvoltagegreaterthan67.5V.When
thisfaultreports,thePTOisdisabled.
CircuitDescription
Eachcuttingunithasanelectriccuttingreelmotorthatcontainsaninternalcontroller.Theinternalcontroller
measures48Vbuspower.
Ifonly1cuttingreelmotorisreportingabusovervoltfault,theproblemislikelytobewiththe48Vpower
connectiontothatcuttingreelmotor.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.GoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Unplugthe48Vbatterydisconnecttopreventunexpectedcuttingunitoperation.RefertoConnectingand
Disconnectingthe48VPowertotheCuttingReelMotors(page18).
3.Swapcuttingreelmotor1withadifferentcuttingunit.Youcanobtainmoreinformationinthecuttingreel
motorsectionofChapter6intheGreensmasterTriFlex3320/3420ServiceManual.
4.Pluginthe48Vbatterydisconnect.RefertoConnectingandDisconnectingthe48VPowertothe
CuttingReelMotors(page18)
5.Operatethemachine.
6.Turnoffthemachine.