EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 112: Internal Regulator Low Voltage - Reel Motor 1

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault112:InternalRegulatorLowVoltage
ReelMotor1
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5001shutsofftheother
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____FAULT#112____
1-INTERNAL
UNDERV
FaultDescription
Insufcientvoltagewasdetectedattheinternalvoltageregulatorforcuttingreelmotor1.Thisfaultcanoccur
ifthecuttingreelmotorunexpectedlylosespower.Forexample,ifthecuttingreelmotorconnectorispulled
apartwhenpowered,thisfaultisreported.
CircuitDescription
Eachcuttingreelmotorhasaninternalvoltageregulator.
Note:Theinternalvoltageregulatorisnotaserviceablepart.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotor1.
1.Locatethe2cuttingreelmotorconnectorsandthee-reelsharnessconnectorsP17andP18.
268

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals