EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Connecting and Disconnecting the 48 V Power to the Cutting Reel Motors; Reading Faults

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ConnectingandDisconnectingthe48VPowertothe
CuttingReelMotors
CAUTION
Beforeinstalling,removing,orservicingthecuttingunits,disconnectthecuttingunitsfromthe
48Vpowersystembyseparatingthecuttingunitpowerconnectors.Thispreventsunexpected
operationofcuttingunits.
1.Parkthemachineonalevelsurfaceandlowerthecuttingunits.
2.Shutofftheengine,applytheparkingbrake,andremovethekeyfromtheignitionswitch.
3.Locatethecuttingunitpowerconnectors,whichareattachedtotheleftframerailneartheoperators
seat(Figure5).
g222909
Figure5
1.Cuttingunitpowerconnectors(48V)2.Operator’sseat
4.Separatethetwoconnectors.
5.Afterworkingonthecuttingunits,applyacoatofdielectricgreasetothepinsinthecuttingunitpower
connectors.
6.Reattachthetwoconnectors.
ReadingFaults
TheInfoCenterdisplayshowsinformationaboutyourmachine,suchasfaults,thechargelevelofthe12V
batteryandthe48Vbatterypack,andvariousdiagnosticmessagesandiconsthatprovidecurrentinformation
aboutthemachine.
18