EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 137: Joystick Broken

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault137:JoystickBroken
InfoCenterDisplay:
_____FAULT#137____
JOYSTICK-INPUT
FaultDescription
ThisfaultisreportedbytheprimaryTECcontrollerwhenitdetectsajoystickLOWERsignalandajoystickRAISE
signalatthesametime.Theremustbeafailedswitchordamagedwiringforthistooccur.
CircuitDescription
Thereare2switcheslocatedonthecontrolarmforthejoystick.Oneswitchisusedtolowerthecutting
units,andtheotherswitchisusedtoraisethem.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:UsingtheInfoCenter,determinewhichswitchisfaulty.
1.SelecttheDIAGNOSTICSscreen.
2.SelectINPUTS.
3.SelectJOYSTICK.
4.Monitorthefunctionoftheswitcheswhilemovingthejoystick.
5.Determinewhichswitchisnotfunctioning.
Pass
Replacethefaultyswitch.GotoReturningtheMachinetoService(page21)andfollowthesteps
listed.
Fail
Neitherswitchindicatedfault.GotoStep3.
Step3:Preparetotestthejoystickswitchesandwiring.
Totestthejoystickswitchesandwiring,rstremovetheconsolecoverasfollows:
1.Removetheeightscrewsthatsecuretheconsolecovertotheundersideoftheconsole(Figure171).This
allowstheconsolecovertomovedownfromtheconsole.
312

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals