Fault74:S3CurrentTooHigh
InfoCenterDisplay:
_____FAULT#74_____
S3COIL-OVER
FaultDescription
ThisfaultisreportedwhentheprimaryTEC-5001controllerdeterminesthattheS3coilcurrentistoohigh.
CircuitDescription
TheprimaryTEC-5001controllerusesinputsfromvariousmachineswitchestodeterminewhentoenergizelift
manifoldsolenoidvalves.OneoutputfromtheprimaryTEC-5001controllerdrivesthecoilforsolenoidS3.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:TesttheresistanceofthecoilforsolenoidS3.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Removetherightsidecover(Figure107).
185