EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 133: Internal TEC Controller Fault

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault133:InternalTECControllerFault
InfoCenterDisplay:
_____FAULT#133____
INT.DEVEL.
FaultDescription
TheprimaryTEC-5001reportsthisfaultwhenitdetectsasoftwarefaultexistswithintheprimaryTEC.
CircuitDescription
TheprimaryTECcontrollermonitorstheconditionofvariousmachineswitchesandsensors(inputs)anddirects
electricalpowertocontrolmachinefunctions(outputs)basedonthestateoftheinputs.TheprimaryTECis
responsibleformanagingtheenginestartsignalandinterlocks.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Shutofftheengine.
3.Starttheengine.
4.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.ContacttheToroTechnicalAssistanceCenterforassistance.
Note:Youmustxthissoftwarefault.AccomplishtheTECsoftwarerepairwithdirectassistance
fromToro.
308