EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 83: Master Contention Fault

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault83:MasterContentionFault
InfoCenterDisplay:
_____FAULT#83_____
MASTERCONTENTION
FaultDescription
TheprimaryTECreportsthisfaultwhenitdetectsthatithasreceivedaCANbusmessagefromanother
primaryTEC.
CircuitDescription
TheprimaryTECmonitorstheconditionofvariousmachineswitchesandsensors(inputs)anddirectselectrical
powertocontrolmachinefunctions(outputs)basedonthestateoftheinputs.IftwoTECsarepresenton
thesameCANbus,theTECswillbeelectricallyidenticalbuttheyareprogrammedinaprimary/secondary
conguration.Theycannotbeinterchangedwithoutbeingreprogrammed.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:UseToroDIAGtoreprogramthemachine.
UseToroDIAGtoreprogramthemachine.Iftherstattempttoreprogramthemachineisunsuccessful,try
reprogrammingthemachineasecondtime.
1.ConnectaPCwithT oroDIAGsoftwaretothemachineviaaT oroDIAGCable(PartNo.115-1944).Refer
toT oroDIAG–QuickStart(page22).
2.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
cuttingreelmotorisreprogrammedduringthereprogrammingofthemachine.
3.DisconnecttheT oroDIAGcablefromthemachine.
Step3:Returnthemachinetoservice.
GotoReturningtheMachinetoService(page21)andfollowthestepslisted.