EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 78: SRV Coil - Overcurrent

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault78:SRVCoil-Overcurrent
InfoCenterDisplay:
_____FAULT#78_____
SRVCOIL-OVER
FaultDescription
ThisfaultisreportedwhentheprimaryTEC-5001controllerdeterminesthattheSRVcoilcurrentistoohigh.
Note:TheSRVsolenoidisalsoreferredtoasthePRVsolenoid.
CircuitDescription
TheprimaryTEC-5001controllerusesinputsfromvariousmachineswitchestodeterminewhentoenergizemow
manifoldsolenoidvalves.OneoutputfromtheprimaryTEC-5001controllerdrivesthecoilforsolenoidSRV.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:TesttheresistanceofthecoilforsolenoidSRV.
1.GotoPreparingforTroubleshootingand/orTesting(page20)andfollowthestepslisted.
2.Removetheleftsidecover(Figure117).
195

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals