EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Fault 121: Invalid Hall State - Reel Motor 1

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault121:InvalidHallStateReelMotor1
InfoCenterDisplay:
_____FAULT#121____
1-INTERNAL
FaultDescription
TheinvalidHallstatefaultindicatesthattheHalleffectsensorsinthecuttingreelmotorareprovidingan
invalidmotorspeedreading.Whenasensorfails,thecuttingreelmotorcannotmaintainsteadyspeedand
becomesunstable.
CircuitDescription
Eachcuttingreelmotorisequippedwithaseriesof3identicalHalleffectsensorstomonitormotorspeed.
Theseareintegraltothecuttingreelmotorandcannotbeserviced.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Swapcuttingreelmotorsbetweencuttingunits.
Allofthecuttingreelmotorsareidentical.
1.RefertoFigure161tolocatecuttingunit1.
286

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals