Fault113:InternalRegulatorLowVoltage
ReelMotor2
Note:Whenanyindividualcuttingreelmotorisshutoffduetoafault,theTEC-5001shutsofftheother
cuttingreelmotors.
Note:Ifmultiplemachinefaultsarereportedwithinafewseconds,troubleshootingshouldbeginwiththe
rstcuttingreelmotortoreportafault.
InfoCenterDisplay:
_____FAULT#113____
2-INTERNAL
UNDERV
FaultDescription
Insufcientvoltagewasdetectedattheinternalvoltageregulatorforcuttingreelmotor2.Thisfaultcanoccur
ifthecuttingreelmotorunexpectedlylosespower.Forexample,ifthecuttingreelmotorconnectorispulled
apartwhenpowered,thisfaultisreported.
CircuitDescription
Eachcuttingreelmotorhasaninternalvoltageregulator.
Note:Theinternalvoltageregulatorisnotaserviceablepart.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Inspectthewiringforcuttingreelmotor2.
1.Infrontoftheleftsidecover,locatethe2cuttingreelmotorconnectorsandthee-reelsharnessconnectors
P19andP20.