Fault47:OvertempBulbCurrentTooHigh
InfoCenterDisplay:
____FAULT#47____
WARN-OVER
FaultDescription
ThisfaultisreportedwhentheovertempbulbcircuitisdrawingtoomuchcurrentfromtheTEC-5001controller.
Note:Theovertempbulbmayalsobereferredtoasthehighwatertemperatureindicatorlight.
CircuitDescription
OneoutputfromtheprimaryTECcontrollerdrivestheovertempindicatorbulb.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:Testtheoutputcircuitforashort.
1.Openuptheoperatorconsoleasneeded,andremovethewarninglampassembly(Figure84).
147