EasyManua.ls Logo

Toro Greensmaster TriFlex 3400 - Page 159

Toro Greensmaster TriFlex 3400
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LocationHarness
Connector
Pin
Wire
Color
Expected
Reading
ConnectorGraphic
1MainP01
7
Pink(PK)
2MainP382
Pink(PK)
lessthan
2ohms
CAUTION
OvertighteningtheharnessconnectorretainingfastenerwilldamagetheprimaryTEC
controller.
AfteryouplugconnectorP01backintotheTEC,torquetheretainingfastenerforP01to25–28
in-lbs.
Pass
Thewiringtestpassed.GotoStep9.
Fail
Thewiringtestdidnotpass.Repairorreplacethefaultywiring.GotoReturningtheMachineto
Service(page21)andfollowthestepslisted.
Step8:Testtheleakdetectoralarm.
1.Removetheleakdetectoralarmfromthemachine.
2.Benchtestusing12Vpowerononeside,andgroundontheother.Thealarmshouldsound.
PassTheleakdetectoralarmtestpassed.Beginthediagnosticprocessagain.
Fail
Theleakdetectoralarmtestdidnotpass.Replacethealarm.GotoReturningtheMachineto
Service(page21)andfollowthestepslisted.
159

Table of Contents

Other manuals for Toro Greensmaster TriFlex 3400

Related product manuals