5.Installtheaccesspanelontotheoutercoverofthecontrolarm.
6.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Step5:Testthecuttingreelmotor1voltage.
Note:Observeproperelectricalsafetyprocedureswhenworkingwithhighvoltage.
1.Pluginthe48Vbatterydisconnect.RefertoConnectingandDisconnectingthe48VPowertothe
CuttingReelMotors(page18).
2.VerifyconnectorP18isunplugged.
3.MovethekeyswitchtotheRUNposition.
4.Useamultimetertotestthevoltagebetweenthepairoflocationsshowninthefollowingtable.
LocationHarness
Connector
Pin
Wire
Color
Expected
Reading
ConnectorGraphic
1e-ReelP181
Red(R)
2e-ReelP182
Black
(BK)
32–67volts
5.ReturnthekeyswitchtotheOFFposition.
6.PluginconnectorP18.
PassThevoltagetestpassed.Repeatthediagnosticprocess.
Fail
Thevoltagetestfailed.TracethevoltagewiringbetweenP18andthe48Vfuseblock.Goto
ReturningtheMachinetoService(page21)andfollowthestepslisted.