Fault145:SoftwareIncompatible
InfoCenter
InfoCenterDisplay:
_____FAULT#145____
-SOFTWARE
Note:TheInfoCentermayalsobecalledthe“Can-Trakdisplay”orthe“mini-infocenter.”
FaultDescription
ThisfaultisreportedwhenthecontrollersoftwareintheInfoCenterisincompatiblewiththesoftwareinthe
primaryTEC-5001controller.
CircuitDescription
Therearemultiplecontrollersinthismachine,includingtheprimaryTEC-5001controllerandindividual
controllerswithineachcuttingreelmotor.Thereareadditionalindividualcontrollerswithinthestarter/generator
unitandtheInfoCenter.Allofthesecontrollersmusthavecompatiblesoftwareforthemachinetofunction
correctly.
RecommendedServiceActions
Step1:Verifythatthefaultrepeats.
1.ClearthesystemfaultsfromtheInfoCenter.RefertoClearingFaultsfromtheInfoCenter(page19).
2.Operatethemachine.
Pass
Thefaultdidnotrepeat.GotoReturningtheMachinetoService(page21)andfollowthestepslisted.
Note:Ifthefaultdoesnotrepeat,anisolatedeventhasoccurred.
Fail
Thefaultrepeated.GotoStep2.
Step2:UseToroDIAGtoreprogramthemachine.
UseToroDIAGtoreprogramthemachine.Iftherstattempttoreprogramthemachineisunsuccessful,try
reprogrammingthemachineasecondtime.
1.ConnectaPCwithT oroDIAGsoftwaretothemachineviaaT oroDIAGCable(PartNo.115-1944).Refer
toT oroDIAG–QuickStart(page22).
2.UsetheToroDIAGsoftwaretoreprogramthemachineinaccordancewithToroDIAGUser’sGuide.The
cuttingreelmotorisreprogrammedduringthereprogrammingofthemachine.
3.DisconnecttheT oroDIAGcablefromthemachine.
Pass
Ifreprogrammingthemachinewassuccessful,gotoReturningtheMachinetoService(page21)
andfollowthestepslisted.
Fail
Ifbothattemptstoreprogramthemachineareunsuccessful,gotoStep3.