g238438
Figure61
1.Alternator2.Temperaturesender
3.UnplugmainharnessconnectorP02fromthecoolanttemperaturesender.
4.InspectharnessconnectorP02andthetemperaturesenderconnectorforthefollowing:
damage
corrosion
debris
properalignmentandseatingofthepinsinsidetheconnectors
PassThewiringinspectioncheckpassed.
LeaveconnectorP02unpluggedfromthetemperaturesender.
GotoStep3.
Fail
Oneormoreoftheinspectionchecksfailed.Repairorreplacethewornordamagedparts.Goto
ReturningtheMachinetoService(page21)andfollowthestepslisted.
Step3:Testthecoolanttemperaturesender.
1.MeasuretheresistanceacrossthepinsofthetemperaturesenderfollowingtheprocedureinChapter6of
theGreensmasterTriFlex3320/3420ServiceManual.
2.Wait10minutestoallowtheenginetocoolandthenmeasuretheresistanceacrossthepinsofthe
temperaturesenderagain.Astheenginecools,theresistanceacrossthepinsofthetemperaturesender
shouldincrease.Thefollowingtableshowssampledataacrossawiderangeoftemperatures.
Temperature
TemperatureSenderResistance
20°C(68°F)
11.4to13.6kohms
30°C(86°F)
7.4to8.75kohms
40°C(104°F)
4.9to5.75kohms
60°C(140°F)
2.3to2.6kohms
95°C(200°F)
740to830ohms
105°C(220°F)
560to630ohms
115°C(240°F)
420to470ohms
97