StartingProblems(continued)
Theenginecranks,butshouldnot,whenthePTOswitchis
intheON(up)position.
ThePTOswitchorcircuitwiringisdamaged.
TheStandardControlModuleisdamaged.
Theenginestarts,butstopswhenthekeyswitchisreleased
fromtheSTARTposition.
Thecircuitwiringisdamaged.
Thekeyswitchisdamaged.
Nothinghappenswhenyouattempttostarttheengine.Thetractionpedalisnotintheneutralposition.
Interlocksystemhasproblem.
Theoperatorseatisunoccupiedortheparkingbrakeis
notapplied.
Thetractionneutralsensorisdamagedoutofadjustment.
ThePTOswitchisintheON(up)positionoritisdamaged.
Theenginecoolanttemperatureisexcessiveortheengine
hightemperatureshutdownswitchisdamaged.
Thebatteryisdischarged.
Thebatterycablesarelooseorcorroded.
Thegroundconnectionislooseorcorroded.
ThefuseF1-1(15A)isdamaged;refertoFuses(Machine
SerialNumberbelow400000000)(page6–22)orFuses
(MachineSerialNumberabove400000000)(page6–23).
Thefuseblockisdamaged.
Thefusiblelinkharnessattheenginestartermotoris
damaged.
Thewiringintheenginecrankcircuitisloose,corroded,
ordamaged;refertotheElectricalSchematicsinAppendix
A(pageA–1).
Thekeyswitchisdamaged.
Thestartersolenoidwiringisloose,corroded,ordamaged.
Thestartersolenoidisdamaged.
TheStandardControlModuleisdamaged.
Groundsmaster
®
3280-D/3320
Page6–11
ElectricalSystem:Troubleshooting
05138SLRevB