GeneralRunandTransportProblems
Problem
PossibleCauses
Theenginecontinuestorun,butshouldnot,whenthekey
switchisturnedtotheOFFposition.
Thebatteryisdischarged.
Thebatterycablesarelooseorcorroded.
ThefuseF1-1(15A)tothekeyswitchisdamaged;refer
toFuses(MachineSerialNumberbelow400000000)(page
6–22)orFuses(MachineSerialNumberabove400000000)
(page6–23).
Thekeyswitchorcircuitwiringisdamaged.
Theengineshutsoffduringtheoperation,butitisableto
startagain.
Note:Iftheexcessivecoolanttemperaturecausesthe
enginetoshutdown,theoperatorcanstarttheengineby
movingthemachinetoashortdistance.Afterstartingthe
engineinthiscondition,theenginerunsforapproximately10
secondsbeforeitshutsoffagain.
Theparkingbrakeisengaged.
Theoperatorisraisingfromtheseat(theseatswitchnot
fullypressed).
Theseatswitchorcircuitwiringisdamaged.
Thekeyswitchorcircuitwiringisdamaged.
Themachineisoperatedonaslopewithalowfuellevel.
Theparkingbrakeswitchorcircuitwiringisdamaged.
Theenginecontinuestorun,butshouldnot,whenthe
tractionpedalispressedwithnooperatorontheseat.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Thetractionneutralsensorisoutofadjustmentordamaged.
Theengineshutsoffwhenthetractionpedalispressedor
thePTOswitchisONwiththeoperatorintheseat.
Theoperatorisraisingfromtheseat(theseatswitchnot
fullypressed).
Theparkingbrakeisengaged.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Theenginecontinuestorun,butshouldnot,whenthePTO
switchisONwithnooperatorintheseat.
Theseatswitchisdamaged.
Theseatswitchwiringisloose,corroded,ordamaged.
Thetractionneutralsensorisoutofadjustmentordamaged.
ElectricalSystem:Troubleshooting
Page6–12
Groundsmaster
®
3280-D/3320
05138SLRevB

Table of Contents