EasyManua.ls Logo

Toro Groundsmaster 3320-D - Page 290

Toro Groundsmaster 3320-D
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TestingtheRelays(continued)
g214499
Figure162
5.Checkthecoilresistancebetweenterminalsthe85and86withamultimeter
(ohmssetting).Theresistanceshouldbeapproximately72ohms(Figure
162).
6.Connectthemultimeter(ohmssetting)leadstorelayterminals30and87.
Thegroundterminal85andapply+12VDCtoterminal86.Therelayshould
makeandbreakcontinuitybetweentheterminals30and87as+12VDCis
appliedandremovedfromterminal86.
7.Disconnectthevoltageandleadsfromtherelayterminals.
8.Replacetherelayiftestingdeterminesthattherelayisdamaged.
9.Iftherelaytestingiscorrectandacircuitproblemstillexists,checkthe
mainwireharness;refertotheElectricalSchematicsandWireHarness
Drawings/DiagramsinAppendixA(pageA–1).
10.Connectthewireharnesselectricalconnectorstotherelayafteryou
completethetesting.
11.Connectthepositive(+)cabletothebatteryandthenconnectthenegative
(-)cabletothebattery;refertoServicingtheBattery(page6–81).
12.Installthecontrolpaneliftheglowrelaywasaccessed.Lowerandsecure
thehoodiftheaccessoryrelayorcabpowerrelaywasaccessed.
ElectricalSystem:TestingtheElectricalComponents
Page6–62
Groundsmaster
®
3280-D/3320
05138SLRevB

Table of Contents

Other manuals for Toro Groundsmaster 3320-D

Related product manuals