Testing(continued)
1
2
g288591
Figure250
1.Tractioncontrolmanifold2.SolenoidvalveSV
C.Thecoilsofthesolenoidvalvesatthefollowinglocationsarethesame.
Resistanceofthesecoilsshouldbeapproximately7.25ohmswhen
testedat20ºC(68ºF):
Steering/LiftmanifoldS10(Figure248).
TractionmanifoldSV(Figure250).
Note:HydraulicsolenoidvalveSV(tractionmanifold)andS10
(steering/liftmanifold)donothavereplaceablecoils.Ifthesesolenoid
coilsfailaresistancetest,replacetheentirevalveassembly(see
CartridgeValveService(page5–158)).
3.Aftertestingiscomplete,connectwireharnesselectricalconnectortothe
solenoidcoil.