Front Reels Turn Too Fast
Cause Correction
VS1 not operating properly. Do electrical
diagnostics to make sure that voltage
is being applied to VS1 and that there is no electri-
cal fault. See Chapter 5 - Electrical System.
Do cartridge service procedure for VS1.
Interchange VS1 with VS2 and check operation. Re-
place VS1 if faulty.
Front Reels Turn in Only One Direction
Cause Correction
S8 not shifting. Do electrical diagnostics to make sure that voltage
i
s being applied to S8 and that there is no electrical
fault. See Chapter 5 - Electrical System.
Do cartridge valve service procedure for valve S8.
Interchange S8 with S9 and check operation. Re-
place S8 if faulty.
Front Reels Stop or Won’t Start – During Backlap Only
Cause Correction
Motors bypa
ssing. Increase flow to motors by adjusting HOC selector
knob.
Load too high for motor. Decrease load
Troubleshooting Page 4 -