Heat Exchanger Bypass Valve
1. Park the machine on a level surface, lower cutting
units, engage parking brake and stop the engine.
2. Remove the heat exchanger bypass valve hex plug
(Fig. 34).
3. Remove the spring and poppet from the housing.
4. Do not interchange part
s with another valve. The
spring used in the heat exchanger bypass valve is
identified by a yellow dye mark, and requires a force of
approximately 5.5 lb. to compress it to a length of
1.28 in.
5. Inspect the poppet and mating seat in the end cap for
d
amage or foreign material.
6. Reinstall the poppet, spring and plug (with shims and
o-ring) into the housing. Tighten the plug to a torque of
30 to 70 ft-lb.
7. Before starting the engine check the oil level in the
d
ifferential housing and add the correct oil as necessary.
Start the engine and let it run for one to two minutes,
then turn the engine off and check the oil level again.
Check the transmission for leaks.
1
Figure 34
1. Heat exchanger bypass valve
Filter Bypass Valve
1. Park the machine on a level surface, lower cutting
units, engage parking brake and stop the engine.
2. Remove the heat exchanger bypass valve hex plug
(Fig. 35).
3. Remove the spring and poppet from the housing.
4. Do not interchange part
s with another valve. The
spring used in the heat exchanger bypass valve is
identified by a red dye mark, and requires a force of
approximately 2.2 lb. to compress it to a length of
1.28 in.
5. Inspect the poppet and mating seat in the end cap for
d
amage or foreign material.
6. Reinstall the poppet, spring and plug (with shims and
o-ring) into the housing. Tighten the plug to a torque of
30 to 70 ft-lb.
7. Before starting the engine check the oil level in the
d
ifferential housing and add the correct oil as necessary.
Start the engine and let it run for one to two minutes,
then turn the engine off and check the oil level again.
Check the transmission for leaks.
1
Figure 35
1. Filter bypass valve
Transmission Repairs Page 4 - 40 Reelmaster
®