Trunnion Seal Replacement
1. Park the machine on a level surface, lower cutting
units, engage parking brake and stop the engine.
2. Remove control linkage from swashplate control shaft
on transmission (see Transmission Control Removal).
3. Remove hex tapping screws retaining trunnion seal
cover to transmission housing (Fig. 31).
4. Remove trunnion seal cover with lip seal and o-ring.
5. Put seal cover i
n an arbor press and press out old
seal. Once removed, the seal is not reusable.
6. Inspect seal cover for damage. Inspect sealing area
on shaft for rust, wear, or contamination. Polish sealing
area on shaft if necessary.
7. Using an arbor press, press seal
into position from
inside of seal cover until it bottoms out in its bore. Be
careful not to damage the seal.
8. Install o-ring ont
o seal cover and retain with petro-
leum jelly.
9. Use a seal installer tool or wrap end of swashplate
control shaft with thin plastic to prevent damage to seal
during installation.
10. Slide seal cover assembly over swashplate control
shaft onto housing. Install hex tapping screws and
tighten to a torque of 6 to 9 ft-lbs.
11. Install control linkage onto transmission
. Check
machine for “creeping” when engine is running with foot
pedal in neutral position. Do Traction Control Neutral
Adjustment if necessary.
1
2
3
4
Figure 31
1. Hex tapping screw (4) 3. O-ring
2. Trunnion seal cover 4. Lip seal
Reelmaster
®
5100-D Page 4 - 37 Transmission Repairs