TEST NO. 7: Reel Drive Motor Efficiency
Reel drive motor efficiency can be tested by blocking
outlet flow from the motor, then measuring flow from the
motor case drain line. Use a graduated container, such
as special tool TOR4077 to measure flow from the motor
case drain line over a 15 second time period (Fig. 23b).
Use the chart to determine the flow (Fig. 23c).
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for
approximately 10
minutes.
2. Lower cutting units, engage parking brake and stop
the
engine.
3. Disconnect the motor case drain hose (small diame-
ter hose) where it connects to traction unit (not at the
motor). Put a steel cap on the fitting at the traction unit.
leave the case drain hose open (Fig. 23a)
4. Disconnect hose from outlet of motor to be tested. Put
a steel cap on the motor fitting. Put a
steel plug in the
disconnected hose (Fig. 23a).
5. Set HOC Selector Knob, located under the instrument
panel, to
position A (full speed). Make sure Backlap
switch is OFF.
tion.
test to prevent personal injury from rotating
Cutting unit reels will rotate when lowered
with Enable/Disable switch in ENABLE posi-
Keep away from cutting units during
reel blades. Do not stand in front of the ma-
chine.
CAUTION
6. Sit on the seat and start the engine. Move throttle to
full speed (approx. 3200 RPM). Move “Enable/Disable”
switch to ENABLE. Move “Lower-Mow/Raise” lever for-
ward to engage cutting units. Have another person
measure flow from the case drain line for 15 seconds,
then move the switch to DISABLE and stop the engine.
TEST RESULTS: Flow not more than 0.5 GPM.
7. If flow is more than 0.5 GPM motor is worn or
damaged and should be repaired or replaced.
1
2
Front
Figure 23a
1. Case drain hose 2. Outlet hose
Figure 23b
This illustration shows flow being blocked by
closing flow restrictor valve on a flow meter
GPM
Milliliters in 15 sec. Ounces in 15 sec.
.1
95 3.2
.2
189 6.4
.3
284 9.6
.4
378 12.8
.5
473 16.0
.6
568 19.2
.7
662 22.4
.8
756 25.6
.9
852 28.8
1.0
946 32.0
Figure 23c
Testing P
age 4 - 32
Rev. B
Reelmaster
®
5100-D