Magnetic Switch (Solenoid) Attraction Test
1. Disconnect the wire from terminal “M” (Fig. 31).
2. Connect a 12 volt battery to the magnetic switch
term
inals “S and “M. The pinion must protrude.
IMPORTANT: Never apply battery voltage to the
starter for longer than 10 seconds.
Figure 31
Magnetic Switch (Solenoid) Holding Test
1. Disconnect the wire from terminal “M” (Fig. 32).
2. Connect a 12 volt battery to the magnetic switch
terminal “S” and the starter body. Pull out the pinion fully.
The pinion must remain at that position even when
released.
IMPORTANT: Never apply battery voltage to the
s
tarter for longer than 10 seconds.
Figure 32
Magnetic Switch (Solenoid) Return Test
1. Disconnect the wire from terminal “M” (Fig. 33).
2. Connect a 12 volt battery to the magnetic switch
term
inal “M” and the starter body. Pull out the pinion fully.
The pinion must return to its original position when
released.
IMPORTANT: Never apply battery voltage to the
s
tarter for longer than 10 seconds.
Figure 33