Solenoid Valve Coil Replacement
1. Park machine on a level surface, engage parking
brake, lower the cutting units and turn engine OFF.
2. Disconnect solenoid electrical connector.
3. Remove nut from solenoid.
4. Remove solenoi
d coil.
5. Install new solenoid coil and secure with nut. Apply
“Locktite 242" or equivalent to threads on end of stem
tube before installing nut. Tighten nut to a torque of
15 in-lb. Over-tightening may damage the solenoid or
cause the solenoid valve to malfunction.
1
Figure 41
6. Connect electrical wiring connector.
1. Solenoid
Solenoid Wire Identification
Solenoid Power W ire Color
1 Pink/Blue
2 Brown/White
3 Orange/Blue
4 Yellow/Black
5 Yellow/W hite
6 Orange/Red
7 Yellow/Blue
8 Black/ Red
9 Brown/White
VS1 Orange/Black
VS2 Orange/White
Figure 42