Reel Motor Removal and Installation
1. Disconnect hydraulic lines. Put caps or plugs on
fittings and hoses to prevent contamination. Tag hydrau-
lic lines for proper reassembly.
2. Loosen motor mount nuts (Fig. 94).
3. Rotate motor clockwise so motor flanges clear studs
and pull motor out.
4. Reverse steps 1 - 3 to reinstall motor.
1
2
Figure 94
1. Motor 2. Motor mount nuts
Reelmaster
®
5100-D Page 4 - 61 Mowing Circuit Repairs