DISASSEMBLY AND REPLACEMENT
4 - 146
4.11.8 Upper exit roller <35ppm/45ppm/50ppm>
(5) While holding the plunger [3] with your hand,
remove the reverse gate solenoid [4] as
shown in the figure on the right.
(6) Remove the plunger [3].
Notes:
When installing, insert the mold at the edge
of the plunger into the groove of the reverse
unit.
Fig. 4-390
Fig. 4-391
(1) Remove the reverse motor unit.
P. 4-144 "4.11.6 Reverse motor (M13)
<35ppm/45ppm/50ppm>"
(2) Remove 2 screws and take off the cover [1].
Fig. 4-392