8
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 45
8.2.5 TopAccess related error/Communication error with external
application
Error
code
Classification Message Contents
Error code display media
Troubles
hooting
Panl JL ML Noti Cf Pjl
5010 Communication
error
Internal setting
error: A print job, a
proof print job, a
private print job, a
print job without a
set department
code, a scan job or
a fax job is
remaining in this
equipment.
------
5012 Communication
error
TOSHIBA Global
remote monitoring
system error
Authentication
error: A temporary
password entered
in this equipment
by downloading
from e-Bridge is
invalid, or the
permanent
password set in e-
Bridge is invalid.
--YY--
5013 Communication
error
TOSHIBA Global
remote monitoring
system error
Communication
error between e-
Bridge:
Communication is
attempted while e-
Bridge is enabled
for some reason
such as a version
upgrade.
--Y---
5014 Communication
error
TOSHIBA Global
remote monitoring
system error
No SSL certificate:
There is no SSL
certificate or the
certificate is not in
a correct file
format.
--Y---
5015 Communication
error
TOSHIBA Global
remote monitoring
system error
Invalid SSL
certificate error:
The SSL certificate
is incorrect
--Y---
5016 Communication
error
TOSHIBA Global
remote monitoring
system error
Expired SSL
certificate error:
The SSL certificate
is expired.
--Y---
5017 Communication
error
TOSHIBA Global
remote monitoring
system error
Other SSL
certificate related
error: The SSL
certificate is
invalid.
--Y---
5018 Communication
error
TOSHIBA Global
remote monitoring
system error
Invalid DNS error:
The DNS address
is incorrect.
--Y---
5019 Communication
error
TOSHIBA Global
remote monitoring
system error
Connection error:
Settings for the
initial URL and
proxy are incorrect.
--Y---